Chlamydia for Psittacines
Real Time PCR Detection Kit
REF: GZEP004| SKU: 317325| BRAND: GZ MED
🦜
Psittacines / Avian
🧪
Swabs / Liquids
⏱️
~ 1 Hour total
📦
8 Complete Monotests
Scientific Description
The Chlamydia for Psittacines Real Time PCR kit is a high-precision molecular diagnostic system developed for the qualitative determination and direct identification of Chlamydia psittaci nucleic acid (DNA) in psittacine birds and other avian species. Utilizing Real Time PCR technology based on high-specificity hydrolysis probes, the kit provides robust diagnostic support for the early detection of systemic or respiratory infections caused by this avian pathogen.
This qualitative test for professional use represents an essential diagnostic support tool for Veterinary Surgeons, Veterinary Practices, and Veterinary Clinics specialized in avian and exotic medicine. Designed for seamless integration into Gangzhu Medical’s PCR VET system, the kit operates on a single dedicated analytical rotor channel for targeted detection of the bacterial analyte. The ready-to-use, lyophilized reagent configuration minimizes manual operation, preventing cross-contamination risks and eliminating dosing errors in clinical settings.
Execution Protocol
- Sample Preparation:
• Liquid samples (EDTA blood, effusions): Transfer 200 µL of liquid sample into the preservation reagent tube and shake vigorously. For urine or clear liquid samples, inoculate 200 µL directly into the “LB” loading well.
• Swabs (fecal, cloacal, oropharyngeal, conjunctival): Collect the biological sample using the provided sterile swab, insert it into the tube containing the dilution/preservation buffer, break the disposable shaft, and shake to dissolve the material. - Automated Nucleic Acid Extraction: Retrieve the required extraction cartridges from the kit and remove the top protective film. Transfer 200 µL of the prepared sample into the lysis well marked “LB”.
- Process Automation: Place the conductive tip into the first position of the extraction cartridge (to the left of the “LB” well). Insert the cartridge into the automated PCR VET extractor and press the “Run” button. The automated magnetic bead extraction phase takes approximately 8 minutes and is announced by an acoustic signal.
- PCR Reaction Setup: Carefully collect 20 µL of purified nucleic acid from the final “EB” elution well using a sterile pipette with a new tip and transfer it directly into the tube containing the lyophilized PCR reagent.If running a positive control, reconstitute the white lyophilized cluster with 100 µL of purified water or Elution Buffer and transfer 20 µL into the dedicated PCR tube.
- Dissolution and Thermal Run Initiation: Reconstitute and completely dissolve the lyophilized reagent by gently tapping the tube with your fingers. Ensure, through light shaking or brief centrifugation (10 seconds), that the entire volume resides at the bottom and that no visible air bubbles remain, preventing background fluorescence interference. Place the tubes into the wells of the Real Time PCR VET thermal cycler, configure the parameters, and start the process.
- Results Interpretation: Analysis is guided by the software interface based on amplification curves and Ct values:
• Positive Result: Presence of a typical “S-shaped” amplification curve and a Ct value < 36.
• Negative Result: Ct value equal to 0 or ≥ 36.

Performance Table
| Sensitivity (LOD) | 1000 copies/mL |
| Reproducibility and Precision | Coefficient of Variation (CV) of Ct values < 5% evaluated on samples repeated consecutively 10 times in total |
| Infection Specificity | High analytical specificity, absence of documented cross-reactions with other non-target pathogens |
| Storage and Stability | Safe storage at temperatures between 4 – 30 °C | Kit validity: 18 months |
Technical opinion: Implementing this molecular diagnostic Real Time PCR kit overcomes the limitations of traditional clinical and culture-based diagnosis in identifying Chlamydia in psittacine birds. The use of stable lyophilized Master Mixes protects the integrity of reactive components, significantly reducing operational errors during pipetting. The integration of the automated workflow with the PCR VET extractor and thermal cycler provides objective analytical support in approximately one hour. The results obtained serve as a diagnostic support tool that must always be evaluated by the Veterinary Surgeon based on clinical findings and the animal’s medical history.
BIOLAB Diagnostici Technical Team – Veterinary Division
Biolab is the exclusive distributor in Italy for GZ MED